SECURUS/Use Cases/Cold room monitoring

Cold room monitoring with temperature alerts

A refrigeration unit fails at night or the cold room door stays open after a delivery. Without monitoring, this may only become apparent during the next inspection. SECURUS cold room monitoring collects temperature readings wirelessly and alerts the people responsible. Your team can investigate and decide how to handle the goods.

Cold room 2Example history · 24 h
00:0006:0012:0018:0024:000612Upper limit 7 °C9.5 °C
Temperature too high · Cold room 2 · 9.5 °C · above 7 °C for 15 min

Example data for illustration. You set the thresholds yourself in the platform.

How it works

From the reading to the right person.

01

Measure

Sensors record readings or events directly on site.

Cold room 2 · 9.5 °C
02

Transmit

Via LoRaWAN to a gateway within range, then through its internet connection to the platform.

03

Check

The platform checks every value against your thresholds, rules and time windows.

Above 7 °C for 15 min
04

Alert

The responsible person receives an SMS or email with location, time and trigger.

Email to store management16:00
Temperature too high
Alert: Cold room 2 · 9.5 °C · above 7 °C for 15 min

How does cold room temperature monitoring work?

A suitable temperature probe measures inside the cold room, refrigerated warehouse or freezer. A LoRaWAN sensor sends readings through a gateway to SECURUS. Each measurement point is assigned to a site and a room. Temperature histories and alerts are available centrally across multiple branches.

For shielded cold rooms, a sensor with an external probe may be useful: the probe measures inside while the radio unit stays outside. Range, accuracy, moisture protection and reception must suit the application. Reception is checked at the actual installation point before handover.

Account for limits, defrost cycles and deliveries

A brief rise in temperature does not always mean refrigeration failure. Defrost cycles, cleaning and deliveries affect air temperature. You and your refrigeration contractor define appropriate limits and timing rules based on the goods, equipment and operational requirements. One universal limit would be inappropriate.

Probe position affects the result. Readings near the evaporator, at the door and between goods will differ. Measured air temperature is also not automatically the core temperature of a food product. Define what the measurement point needs to tell you before installation.

Open cold room door: understand temperature changes

An additional door contact shows whether the cold room door is open or closed. It complements temperature readings: an open door often explains a temperature increase better than the reading alone. The team can check for obstructions or a seal that needs inspection.

Door contacts and temperature sensors do not replace refrigeration maintenance. They make selected conditions visible. If temperature rises with the door closed, diagnosis remains the refrigeration contractor’s responsibility.

Temperature alerts by SMS and email

A temperature alert must reach someone responsible outside opening hours too. Set notification groups for branch managers, building technicians or service partners. The message identifies the site and measurement point. Agree responsibilities and cover arrangements before the first alert.

After an alert, the team checks the situation on site. Measures to protect or assess goods follow your operating procedures. A notification alone cannot guarantee a response or that stored products remain unaffected.

Temperature records for your HACCP plan

Historical readings and CSV exports support temperature records in retail, hospitality, canteens and care facilities. Your team can trace when a deviation began and how temperatures developed afterwards. This supports operational reviews and coordination with service teams.

SECURUS supports documentation within your HACCP plan. This does not constitute blanket HACCP certification. Required checks, calibration, retention periods and supplementary records depend on your business and applicable requirements.

Cold room monitoring across multiple sites

For retailers and branch networks, measurement points are organised by branch and refrigerated area. In care facilities, kitchens and housekeeping may be involved; in municipal properties, canteens, childcare facilities or event venues. The measurements are similar, but responsibilities differ.

Start with areas where an unnoticed failure would be particularly serious. Verify measurement points, reception and alert recipients in a pilot installation before extending monitoring to other rooms and sites.

In practice

Set up cold room monitoring for everyday use

Plan measurements with kitchen staff, branch managers and refrigeration contractors so readings and responses fit actual procedures.

Choose a measurement point, not just any reading

A probe at the door, near the evaporator or among goods faces different conditions. Define what the reading needs to tell you and check the location with the refrigeration contractor.

Test everyday situations

Deliveries, cleaning and defrosting are normal operations. During commissioning, check that rules handle these situations while still flagging relevant deviations.

Test the entire notification path

Test measurement, transmission and notification together. Agree who has access at night, investigates the cause and arranges assessment of goods.

FAQ

Frequently asked questions about cold room monitoring

Can SECURUS monitor a freezer?

Yes, provided the sensor and probe support the required temperature range. They are selected to suit the equipment.

Does the sensor need Wi-Fi in the cold room?

No. The sensor uses LoRaWAN. The gateway needs a suitable internet connection to the platform.

Can I receive temperature alerts by SMS?

SMS and email notifications are available. Recipients and rules are configured in SECURUS.

Is the solution HACCP certified?

We do not claim blanket HACCP certification. Historical readings and exports support your operational temperature records.

Can I compare several cold rooms?

Yes. Measurement points can be assigned to rooms and sites and viewed centrally.

Does a temperature probe detect an open door?

Temperature readings alone do not prove a door is open. An additional magnetic contact measures door state directly.

Which parts of the cold chain can I monitor?

The solution described here monitors fixed cold storage areas such as cold rooms, display chillers and freezers. End-to-end cold chain monitoring, including transport and handovers, requires an additional measurement and documentation plan.

More use cases

Server room · Plant room

Temperature monitoring

Monitor temperatures in server rooms, plant rooms and storage areas.

Server room B1: 23.5 °C
Boiler room · Apartment building

Heating monitoring

Track fault contacts and flow and return temperatures.

Flow Building A: 62 °C
Basement · Sanitary

Leak detection

Detect water at risk points and send targeted alerts.

Boiler room: dry
Classroom · Office

Air quality and indoor climate

Review CO₂, temperature and humidity by room.

Room 2.14: 840 ppm
Basement · Shared rooms

Mould prevention

Track humidity patterns and assess mould risk.

Basement A: 72 %
Production · Heating

Machine and equipment monitoring

Fault contacts and condition data from pumps, motors and machines.

Pump 3: running
Buildings · Stores

Energy monitoring

Understand equipment electricity demand and consumption trends.

Town hall: 38.2 kWh
Storage · Cold store

Door and window monitoring

Monitor open and closed states using rules suited to your operating hours.

Loading gate 1: closed
Room · Bathroom

Fall detection

Detect potential fall events without cameras.

Room 12: Fall detected
Reception · Sales floor

SOS and service button

Request help or service at the push of a button.

Reception: ready
Store · Sanitary

Occupancy and people counting

Utilisation of rooms, seats and spaces.

Entrance: 126 people
School WC · Corridor

Smoke and vape detection

Detect smoking in toilets and stairwells.

WC 1st floor: normal
Sanitary · Tanks

Level monitoring

Service tanks, containers and dispensers according to need.

Soap dispenser: 62 %
Corridor · Stairwell

Noise level

Measure noise objectively instead of guessing.

Stairwell A: 42 dB
Heating · Pipes

System pressure

Detect pressure loss in heating and pipes early.

Heating circuit: 1.8 bar
Water · Gas · Electricity

Utility meters

Read water, gas and electricity meters automatically.

Water meter: 12.4 m³
Hot water · Storage tank

Drinking water hygiene

Document hot water and pipe temperatures.

Circulation: 58.4 °C
Swimming pool · Process

Water quality and pH monitoring

Monitor pH, conductivity, chlorine and oxygen.

Swimming pool: pH 7.2
Office · Outdoor area

Lighting monitoring

Detect unnecessary lighting and dark areas.

Office 3rd floor: Lights on
Street trees · Parks

Green spaces and soil moisture

Water trees and green spaces when they need it.

Street tree 114: 23 %

Monitor your cold rooms

Tell us about your cold storage areas, temperature requirements and locations. We will plan suitable probes, wireless coverage and alert recipients.