SECURUS/Use Cases/Energy monitoring

Energy monitoring for buildings and technical equipment

Which equipment keeps running after hours? Where is the base load rising? Energy monitoring reveals the electricity demand of individual systems and areas. SECURUS displays measured current and calculated consumption trends so you can review schedules and assess energy-saving measures.

North sports hallExample history · 24 h
00:0006:0012:0018:0024:0003060Upper limit 30 kWh52 kWh
Unusual consumption · North sports hall · 52 kWh

Example data for illustration. You set the thresholds yourself in the platform.

How it works

From the reading to the right person.

01

Measure

Sensors record readings or events directly on site.

North sports hall · 52 kWh
02

Transmit

Via LoRaWAN to a gateway within range, then through its internet connection to the platform.

03

Check

The platform checks every value against your thresholds, rules and time windows.

Above 30 kWh · After closing time
04

Alert

The responsible person receives an SMS or email with location, time and trigger.

Email to energy management21:00
Unusual consumption
Alert: North sports hall · 52 kWh

From current to kWh and costs

Current sensors measure the current on each cable without touching the wiring. The mains voltage and further details of the installation are stored in SECURUS; from these, the platform calculates consumption in kWh and, with your electricity price, the costs.

The values are indicative estimates and do not replace an electricity or energy meter. The meter records total consumption; measuring individual equipment shows how it is made up. Installation in the distribution board is carried out by a qualified electrician.

Where it pays to look

Typical candidates are refrigeration, pumps, ventilation and equipment with long running times. A high load on the weekend need not be a fault, as refrigeration keeps running, for example; what matters is the comparison with actual demand. After a change, such as new operating hours, the history shows what it achieved. For existing meters, there is remote meter reading.

Compare consumption across sites

Compare similar equipment over the same period, allowing for usage and operating hours. A larger school will usually consume more than a smaller one. More useful questions are whether equipment runs outside scheduled hours or draws less current after a change. For municipal buildings and retail sites, name monitoring points consistently by site and equipment.

FAQ

Frequently asked questions about energy monitoring

How much can I save?

That depends on your equipment. SECURUS shows where energy is being wasted; you save by changing settings or operating hours there.

Can the values be used for billing?

No. They are calculated indicative estimates for analysis and comparison, not a calibrated meter.

Does every piece of equipment have to be measured separately?

No. Start with the equipment that draws the most power or runs the longest.

Can I compare high-consumption equipment across buildings?

Yes. Measurement points are assigned to equipment and sites. Compare similar systems and account for operating hours and use.

More use cases

Server room · Plant room

Temperature monitoring

Monitor temperatures in server rooms, plant rooms and storage areas.

Server room B1: 23.5 °C
Boiler room · Apartment building

Heating monitoring

Track fault contacts and flow and return temperatures.

Flow Building A: 62 °C
Cold room · Freezer

Cold room monitoring

Monitor cold rooms and freezers with temperature alerts.

Cold room 2: 4.2 °C
Basement · Sanitary

Leak detection

Detect water at risk points and send targeted alerts.

Boiler room: dry
Classroom · Office

Air quality and indoor climate

Review CO₂, temperature and humidity by room.

Room 2.14: 840 ppm
Basement · Shared rooms

Mold prevention

Track humidity patterns and assess mold risk.

Basement A: 72 %
Production · Heating

Machine and equipment monitoring

Fault contacts and condition data from pumps, motors and machines.

Pump 3: running
Storage · Cold store

Door and window monitoring

Monitor open and closed states using rules suited to your operating hours.

Loading gate 1: closed
Room · Bathroom

Fall detection

Detect potential fall events without cameras.

Room 12: Fall detected
Reception · Sales floor

SOS and service button

Request help or service at the push of a button.

Reception: ready
Store · Sanitary

Occupancy and people counting

Utilization of rooms, seats and spaces.

Entrance: 126 people
School WC · Corridor

Smoke and vape detection

Detect smoking in restrooms and stairwells.

WC 2nd floor: normal
Sanitary · Tanks

Level monitoring

Service tanks, containers and dispensers according to need.

Soap dispenser: 62 %
Corridor · Stairwell

Noise level

Measure noise objectively instead of guessing.

Stairwell A: 42 dB
Heating · Pipes

System pressure

Detect pressure loss in heating and pipes early.

Heating circuit: 1.8 bar
Water · Gas · Electricity

Utility meters

Read water, gas and electricity meters automatically.

Water meter: 12.4 m³
Hot water · Storage tank

Drinking water hygiene

Document hot water and pipe temperatures.

Circulation: 58.4 °C
Swimming pool · Process

Water quality and pH monitoring

Monitor pH, conductivity, chlorine and oxygen.

Swimming pool: pH 7.2
Office · Outdoor area

Lighting monitoring

Detect unnecessary lighting and dark areas.

Office 4th floor: Lights on
Street trees · Parks

Green spaces and soil moisture

Water trees and green spaces when they need it.

Street tree 114: 23 %

Start with an energy question